Keeping Winston-Salem's Industrial Power Systems Safe, Smart, and Reliable

Winston-Salem has always been a city that makes things. From the tobacco and textile history that built it to today’s advanced manufacturing, healthcare, food processing, and research facilities, the Triad runs on dependable electrical power. Behind the scenes, though, many facilities are running on switchgear, breakers, and distribution equipment that was installed decades ago and hasn’t had the attention it deserves.

That’s where Infinity TSD comes in. Infinity TSD is a NETA-accredited electrical power system service provider founded by a team of industry professionals who share a passion for solving electrical operation, maintenance, and end-of-life problems. Whether you’re just getting started or dealing with a complex, multi-building facility, they can help with every step of the journey. Here are four of the most common challenges Winston-Salem facility managers face, and how to approach them.

  1. Starting an Electrical Maintenance Program

Many plants operate on a “run it until it breaks” basis. It works, until a breaker fails to trip, a cable terminates badly, or an unplanned outage halts production. A structured electrical maintenance program turns that gamble into a plan.

A solid program typically starts with an electrical distribution equipment survey: a documented inventory of what you have, what condition it’s in, and how critical it is to operations. From there, you can build a schedule for preventive maintenance and testing on medium and low voltage switchgear, protective devices, and cabling, prioritized by risk and age. The payoff is fewer surprises, longer equipment life, and budgets you can forecast instead of scrambling to find after a failure.

  1. Tackling Arc Flash Safety Mitigation

Arc flash is one of the most serious hazards in any facility with energized electrical equipment. Compliance with NFPA 70E isn’t just a regulatory box to check. It’s about making sure the people working on and around your equipment go home safe.

Effective arc flash mitigation usually includes:

  • Up-to-date studies and labeling that reflect your system as it exists today, not as it was drawn ten years ago
  • Maintained protective devices, since an arc flash calculation assumes breakers and relays will operate as designed
  • Engineering controls and equipment upgrades that reduce incident energy at the source
  • Training and procedures so your team understands the hazards and the boundaries

Facilities that have added load, changed utility sources, or modified their distribution systems over the years are especially likely to have outdated arc flash data.

  1. Upgrading to the Latest IoT Devices

Modern power monitoring and asset monitoring can change how you manage your electrical system. Instead of discovering a problem when something trips, connected sensors and monitoring devices can help you see trends in loading, temperature, and power quality before they become failures.

Retrofitting power monitoring into existing gear often costs far less than replacing the equipment, and the data helps you make better decisions about when to maintain, when to upgrade, and where capacity is available for expansion. For Winston-Salem’s mix of manufacturers, data-driven facilities, and healthcare operations where uptime matters, that visibility is increasingly a competitive advantage.

  1. Finding the Best Path Forward with Aging Infrastructure

Every piece of electrical equipment eventually reaches end of life. The hard question is what to do about it. Options generally include:

  • Maintain and extend: continue testing and servicing equipment that is still in good condition
  • Retrofit or retrofill: modernize breakers or components inside existing gear
  • Replace: install new equipment as part of a planned, turnkey upgrade

The right answer depends on parts availability, condition testing results, safety considerations, and your production schedule. A feasibility study and lifecycle assessment helps you compare options with real data, so you can plan capital spending on your timeline rather than during an emergency shutdown.

Why a Single Partner Matters

Maintenance, arc flash compliance, monitoring, and lifecycle planning are all connected. Infinity TSD’s capabilities span electrical equipment surveys, NFPA 70E arc flash compliance solutions, maintenance programs, power system and asset monitoring, custom equipment solutions, feasibility consulting, and turnkey equipment upgrades. Their services also include medium voltage cable termination, splicing, and testing, along with medium and low voltage switchgear PM and testing. Working with one team that understands how these pieces fit together helps avoid gaps and finger-pointing.

With offices in Belmont and Raleigh, North Carolina, and Spartanburg, South Carolina, Infinity TSD is well positioned to support facilities across the Carolinas, including the Winston-Salem and Triad area.

Ready to Take the Next Step?  Give us a call

If your facility is dealing with an aging switchgear lineup, uncertain arc flash labels, or no formal maintenance plan at all, a conversation is a good place to start. Visit infinitytsd.com or call 833-873-4897 to talk with their team about where your electrical system stands and what the best path forward looks like.

Some of our markets:

  • Industrial facilities
  • Hospitals
  • Warehouses
  • Office Buildings
  • Data Centers
  • Churches
  • Schools

We are committed to excellence, and we want to show you what separates our company from the rest.